CDGMW - 853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 3 DILUENT
- MSDS: CDGMW
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 3 DILUENT
- National Stock Number: 6550-00D006246
Product Identification
Product ID:853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 3 DILUENT
MSDS Date:04/20/1994
FSC:6550
NIIN:00D006246
Kit Part:Y
MSDS Number: CDGMW
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 800- 242-2424
Cage: 19139
Contractor
Telephone: 800-828-6203
Cage: 5K871
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: >99%
SODIUM BICARBONATE
CAS: 144-55-8
RTECS: VZ0950000
Fraction By Weight: <1%
ETHYL ALCOHOL (ETHANOL)
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: <1.0%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM; 9596
AMMONIUM CHLORIDE (CERCLA)
CAS: 12125-02-9
RTECS: BP4550000
Fraction By Weight: <1%
OSHA PEL 10 MG/M3
ACGIH TLV: 10 MG/M3 FUME; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:TLV: ETHANOL: 1000 PPM
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPECTED TO BE A LOW
HAZARD FOR RECOMMENDED HANDLING. EYES: NO SPECIFIC HAZARD KNOWN.
MAY CAUSE TRANSIENT IRRITATION. SKIN: LOW HAZARD FOR RECOMMENDED
HANDLING. INGESTION: EXPECTED TO BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSISTS. EYES-ANY MATERIAL THAT CONTACTS THE
EYE SHOULD BE WASHED OUT IMMEDIATELY WITH WATER. GET MEDICAL
ATTENTION IF SYMPTOMS OCCUR. SKIN: WASH WITH SOAP & WATER. GET
MEDICAL ATTENTION IF SYMPTOMS OCCUR. INGESTION: DRINK 1-2 GLASSES
OF WATER. SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL,
THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE
THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
AT OR BELOW -18C.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE WORN.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES.
Work Hygienic Practices:IT IS A GOOD INDUSTRIAL HYGIENE PRACTICE TO
MINIMIZE SKIN CONTACT. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
KEY6: N1. PART OF A KIT. KEEP OUT OF REACH OF CHILDREN. LOW HAZARD FOR
RECOMMENDED HANDLING.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.0
pH:7.0
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID. COLORLESS. ODORLESS.
Percent Volatiles by Volume:99
Stability
Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE
AMOUNTS OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their